Interpolation compatibility
We talked about the rule before, and now it’s time to put it to work. For any two instances within your parameter space, it’s essential that every contour yields the same number of Bézier segments with the same point types. This consistent structure is precisely what interpolation between masters requires—think of point 3 of a light o needing to correspond perfectly to point 3 of a black o. It’s also the fundamental promise that our future designspace sampler will rely on when it’s ready to cut masters from a single ductus source.
Why you mostly can’t break it
Good news: Ductus is designed to prevent you from breaking this rule almost entirely. It’s baked right into the core design of the language itself. The number and type of on-curve points in a contour are determined by your source text, not by the values of your parameters. When you adjust a parameter, you’re moving coordinates, never changing the underlying topology. We’ve thoughtfully shaped every construct that could potentially threaten this rule to keep it safe:
- Shape constructors inherently have fixed point counts. For instance, an
ellipse()will always result in eight points. That’s why you’ll findellipse(c, r, r)rather than a separatecircle(c, r)function. - You won’t find boolean geometry or “remove this point if” conditions here. We also don’t use conditional statements that alter structure. Instead, Ductus offers conditional expressions, which simply select between different values.
- A witness node, like one created by
directionpoint, will consistently be a single point at every instance, no matter where its crossing point happens to move.
Want to double-check yourself, or see how the tooling thinks about it? Point counts are readily available in ductus inspect:
glyph o
advance 636
contour outer 4 points
contour inner 4 points
If you see the same counts when you run ductus inspect with --set weight=100 and again with --set weight=900, you know your masters are compatible.
The trapdoors
Even with Ductus’s protective design, there are still three specific constructs where you might accidentally introduce a topology change. We made sure to flag all of these when we introduced them in earlier language chapters:
- Conditionals over geometry choices. Something like
r if weight < 500 else 0is perfectly fine, as it simply chooses a number. It’s also fine to use a conditional to swap between different constructions for a contour, provided that both options result in the exact same number of points. What you absolutely must avoid is creating arms with different point counts. We refer to this specific limitation as the intended-use boundary in the conditional chapter. forbounds that depend on a parameter. Imagine wanting one decorative element per 100 units of weight. This approach would mean your light master and your black master end up with entirely different contours, which is a no-go for interpolation.- Count arguments. When
superellipse(c, rx, ry, n, count)asks for its point count as an argument, it’s precisely because that count needs to stay constant. If you pass in acountthat’s derived from a parameter, you’re reintroducing the very problem that these constructors were designed to avoid.
The evaluator doesn’t currently police any of these situations in v0.1. Until the sampler arrives, keeping the rule solid is on you. The good news is that running ductus inspect at the corners of your design space offers a super quick audit.
The other failure mode: existence
Even if your topology is perfectly stable, there’s another kind of hiccup that can occur: an instance might still fail to evaluate. Think of it this way: sometimes your design asks for something that simply isn’t there in a particular instance. Whether something exists can, in turn, depend on your parameters:
- A
directionpoint(skel, pen_angle)witness only comes into existence while the skeleton’s tangent actually sweeps through thatpen_angle. If you rotate the pen axis past the sweep of a leg, that specific instance will lead to an error. - An
intersection()between a serif line and a diagonal will only exist if the diagonal reaches far enough to actually cross the serif. clamp(x, lo, hi)will signal an error if a parameter-derivedlovalue ever manages to overtakehi.
A great example of this in action lives in latin_set.ductus from the playground. Its header carefully documents a real-world case: the pen_angle range is intentionally narrowed to ensure that a specific witness node on one leg of the a is present across the entire design space. For now, the best strategy is to choose parameter ranges so every query stays satisfiable, and then make sure to note this constraint in a comment where you declare the range. Want a quick way to check this yourself? Building at each corner of your design space offers a straightforward regression test:
ductus check family.ductus
ductus build family.ductus --set weight=100 -o /dev/null
ductus build family.ductus --set weight=900 -o /dev/null
When our designspace sampler eventually joins the party, it will take on the important task of exploring the entire space and reporting both incompatibilities and unsatisfiable queries.